Digital Radiography Mobile X-ray System - MobileDaRt Evolution MX9 Standard Version v type
(Para verificar las características detalladas de cada tipo de MobileDaRt Evolution MX9 Version, haga clic en los botones de las pestañas de arriba).
Features of s type
Smart DSI: Retained Object Confirmation Support Image Processing OPTION
Developed with AI technology, Smart DSI aids the detection of objects retained in the body by enhancing regions of the image that potentially show surgical needles, gauze with radiopaque threads, and other foreign objects.*1)
Haga clic aquí para ver la página de solo video
*The Smart DSI application in this video is demonstrated on the MobileDaRt Evolution MX8 Version c type.
The user interface and screen layout differ from those on the MX9 Version v type.

Display images processed by Smart DSI *2)

Processed image by Smart DSI
- *1) The AI (artificial intelligence) technology used in Smart DSI is not a self-guided interactive learning-type AI.
- *2) Do not rely solely on the imaging processing capabilities of Smart DSI when determining if foreign objects are retained in the patient. Use visual confirmation of images, gauze counts, and other methods in reaching a final judgement.
Haga clic aquí para ver la página de solo video
Smart DSI User Testimonial – Island Hospital, USA
*The Smart DSI application in this video is demonstrated on the MobileDaRt Evolution MX8 Version c type.
Smart Tube : Tube and Catheter Verification Support Software OPTION
Developed with AI technology, Smart Tube enhances potential areas of tubes and catheters from images, supporting position verification. *1)

Display images processed by Smart DSI *2)

Processed image by Smart Tube
- *1) Do not rely solely on the imaging processing capabilities of Smart Tube when verifying tubes or catheters. Use visual confirmation of images or other methods in reaching a final judgement.
- *2) The AI (artificial intelligence) technology used in Smart Tube is not a self-guided interactive learning-type AI.
Smart Noise Reduction OPTION
La reducción inteligente del ruido ayuda a reducir la dosis de radiación sin modificar la calidad de la imagen. This software provides versatility for various examinations and user-friendly operation.
con dosis estándar (100 %)
75kVp, 20mAs
con dosis reducida(50 %)
75kVp, 10mAs
Scatter Correction enables Grid-less Radiography OPTION
The system can be equipped with a function to remove scatter noise and improve image contrast, making it possible to perform exposures without the use of a grid therefore making it easier to handle FPDs.

Seleccione el FPD perfecto para su aplicación
Hay una amplia variedad de modelos de FPD disponibles para satisfacer diversas necesidades clínicas, como el tamaño físico y la sensibilidad. Puede compartir un FPD entre varias unidades o añadir FPD de diferentes dimensiones. Una combinación con FPD de peso liviano y resistente a los líquidos facilita en gran medida su manejo diario. *)
*) It depends on FPD models.


Tenga en cuenta que es posible que el producto o algunas características/opciones no estén disponibles en su país.
El aspecto del sistema, las opciones, la interfaz de usuario de FPD y DR pueden ser diferentes según la versión o la región, y pueden cambiar sin previo aviso. Para confirmar esta disponibilidad detallada, comuníquese con nosotros.
División de Sistemas Médicos, Shimadzu Corporation
Global Marketing Department, Medical Systems Division, Shimadzu Corporation1
Research & Development Department, Medical Systems Division, Shimadzu Corporation2
Departamento de Radiología, Shiroyama Hospital
Departamento de Radiología, Centro Médico Ohashi de la Universidad de Toho
Departamento de Radiología, TMG Asaka Medical Center