Open Solution
Ultra High-Performance Liquid Chromatograph
| Part Name | P/N | Description |
|---|---|---|
| CBM-40lite | 228-65501-58 | System controller that can control up to 4 units, and is built into the solvent delivery unit for use. |
| SSU-40 | 228-65091-58 | Solvent switching and degassing unit that is connected to the solvent delivery unit (LC-40B X4) for use. Each pump can switch between up to 4 solvents (supports up to 2 pumps) and degas up to 5 flow paths. |
| DGU-403 | 228-65088-58 | Degassing unit that is connected to the solvent delivery unit for use, and can degas up to 3 flow paths. |
| DGU-405 | 228-65089-58 | Degassing unit that is connected to the solvent delivery unit for use, and can degas up to 5 flow paths. |
| Micro mixer 2 uL | 228-85283-41 | 2 uL mixer for high-pressure gradient systems. |
| High-pressure gradient mixer MR20 μL | 228-72652-41 (With mixer recognition device) |
20 μL mixer for high-pressure gradient systems. |
| 228-45209-41 (Without mixer recognition device) |
||
| High-pressure gradient mixer MR40 μL | 228-72652-42 (With mixer recognition device) |
40 μL mixer for high-pressure gradient systems. |
| 228-45209-42 (Without mixer recognition device) |
||
| High-pressure gradient mixer MR100 μL | 228-72652-43 (With mixer recognition device) |
100 μL mixer for high-pressure gradient systems. |
| 228-45209-43 (Without mixer recognition device) |
||
| High-pressure gradient mixer MR180 μL II | 228-72652-44 (With mixer recognition device) |
180 μL mixer for high-pressure gradient systems. |
| 228-45209-44 (Without mixer recognition device) |
| Part Name | P/N | Description | |
|---|---|---|---|
| Sample loop |
15 μL | 228-63132-46 | Sample loop for 15 μL injection. |
| 50 μL | 228-63132-44 | Sample loop for 50 μL injection. (standard configuration of SIL-40 XR/40C XR/40C XS/40C X3/40C X4) |
|
| 100μL | 228-63132-45 | Sample loop for 100 μL injection. (standard configuration of SIL-40/40C) | |
| 500 μL | 228-45405-45 | Sample loop to increase the injection volume up to 500 μL. Used in connection with sample loop 100 μL. (228-63132-45) |
|
| 2000 μL | 228-45405-46 | Sample loop to increase the injection volume up to 2 mL. Used in connection with sample loop 100 μL. (228-63132-45) | |
| Nexlock™ II sample loop for loop injection | 5 μL | 228-71759-47 | Sample loop for 5 μL injection to use in the loop injection mode. |
| Sample plate | 1.5 mL | 228-71762-46 | Plate for holding 54 × 1.5 mL sample vials. |
| 1 mL | 228-71762-42 | Plate for holding 84 × 1 mL sample vials. | |
| 4 mL | 228-71762-43 | Plate for holding 28 × 4 mL sample vials. | |
| 10 mL | 228-71762-44 | Plate for holding 12 × 10 mL sample vials. | |
| Identification label | For 96-well microtiter plates | 228-71840-41 | Identification label affixed to the 96-well microtiter plate. (100 set) |
| For 96-well deep-well plates | 228-71840-42 | Identification label affixed to the 96-well deep-well plate. (100 set) | |
| For 384-well microtiter plates | 228-71840-43 | Identification label affixed to the 384-well microtiter plate. (100 set) | |
| For 384-well deep-well plates | 228-71840-44 | Identification label affixed to the 384-well deep-well plate. (100 set) | |
| Part Name | P/N | Description | |
|---|---|---|---|
| Active pre-heater | 228-72084-41 | Heater that individually controls the temperature of the column IN tubing, and heats the mobile phase before it flows into the column. | |
| FCV kit | For CTO-40S | 228-72438-41 | Kit for attaching a flow line switching valve to CTO-40S. |
| For CTO-40C | 228-72589-41 | Kit for attaching a flow line switching valve to CTO-40C. | |
| FCV tubing kit with 2 tubes | ID 0.3 | 228-72437-41 | Tubing kit to connect the flow line switching valve and columns. |
| ID 0.1 | 228-72437-42 | ||
| FCV tubing kit with 6 tubes | ID 0.3 | 228-72437-43 | |
| ID 0.1 | 228-72437-44 | ||
| Nexlock II LD | ID 0.1 × 600 mm | 228-87372-41 | Low-diffusion tubing with hand-tightened, high pressure-resistant fittings for use on the column IN side. |
| Part Name | P/N | Description |
|---|---|---|
| High-sensitivity cell | 228-65355-41 | High-sensitivity cell with significantly improved trace component detection sensitivity, having a cell volume of 4.2 μL and an optical path length of 85 mm. |
| Part Name | P/N | Description |
|---|---|---|
| Power outlet unit 6P | 228-65523-41 | Power strip to completely turn off the instrument’s main power at once. Switches can be installed in front of the reservoir tray. It provides 6 outlets. |
| Power outlet unit 2PS | 228-65524-58 | Outlet to supply power to main units that need to be connected to service outlets, such as SIL-10A and FRC-10A. It provides 2 outlets. |
| Nexlock II LD tubing kit,ID 0.1 for high-pressure GE | 228-85453-41 | Nexlock II LD tubing kit for high-pressure gradient system. It includes a sample loop for 15 μL injection, an autosampler OUT tube with an internal diameter of 0.1 mm, and a micro mixer 2μL. |
| Nexlock II LD tubing kit,ID 0.1 for low-pressure GE | 228-85453-42 | Nexlock II LD tubing kit for low-pressure gradient system. It includes a sample loop for 15 μL injection, an autosampler OUT tube with an internal diameter of 0.1 mm, and a design plate for the Nexera X3. |
| Nexflow tubing for MS, ID 0.1 | 228-85452-41 | Nexflow tubing kit for MS front system. It includes a low-volume coupling for MS connections, a column OUT tube with an internal diameter of 0.1 mm, and an ESI coupling IN tube. |
| Nexflow tubing for MS, ID 0.064 | 228-85452-42 | Nexflow tubing kit for MS front system. It includes a low-volume coupling for MS connections, a column OUT tube with an internal diameter of 0.064 mm, and an ESI coupling IN tube. |
| Cable kit A | 228-70247-41 | Optical fiber cable kit, 600 mm × 1, 800 mm × 1 |
| Cable kit B | 228-70247-42 | Optical fiber cable kit, 600 mm × 2, 800 mm × 1 |
| Cable kit C | 228-70247-43 | Optical fiber cable kit, 600 mm × 3, 800 mm × 1 |
| Cable kit D | 228-70247-44 | Optical fiber cable kit, 600 mm × 4, 800 mm × 1 |
| Reservoir tray | 228-65508-58 | Tray on which up to 8 mobile phase bottles (1 L) can be placed. |
| AD board | 228-55519-41 | Board for analog–digital conversion. It takes in detector signals as analog signals. |
| Optical cable connector expansion board | 228-70481-41 | The board to expand the number of optical cable connector channels to 12ch from 8ch (standard) by attaching to SCL-40/CBM-40. |